Agilent FieldFox RF Analyzer
N9912A 4/6 GHz
Technical Overview
Carry precision with you.
Vista de página 0
1 2 3 4 5 6 ... 28 29

Resumo do Conteúdo

Página 1 - Agilent FieldFox RF Analyzer

Agilent FieldFox RF Analyzer N9912A 4/6 GHzTechnical OverviewCarry precision with you.

Página 2

Network analyzer time domainWith the time domain Option, FieldFox com-putes the inverse Fourier transform of the frequency-domain data to display re

Página 3 - Handheld RF Analyzer

11sensorFieldFox can connect with the Agilent USB power sensors to make average power mea-surements up to 40 GHz. Using USB

Página 4

testReturn loss/VSWR measurements allow you to evaluate

Página 5

1313continuedIndependent signal sourceProvides a test signal to measure coverage, antenna isolation, long cable

Página 6

14Transflective display makes it easy to read measurements in direct sunlightWater resistant chassis withstands wide temperature ranges and humid envir

Página 7

FieldFoxWarranted performance. Specifications include guardbands to account for the expected statistical performance distributio

Página 8

16FieldFox  2 MHz to 4 GHz 60 dB (typical) > 4 GHz to 6 GHz 55 dB (typical) 

Página 9

17FieldFox Return loss  0 to 100 dB Resolution 0.01 dB   0 to 100 Resolution

Página 10 - FieldFox

FieldFox S11 Vector measurement, S11 magnitude and S11 phase. Specification is listed under Cable and antenna

Página 11

19FieldFoxFrequency Frequency range    100 kHz to 4 GHz, usable to 5 kHz  100 kHz to 6

Página 12

2FieldFoxEvery piece of gear in your kit had to prove its worth. Measuring up and earning a spot is the driving idea behind Agilent’s FieldFox RF anal

Página 13

Amplitude Measurement range Displayed average noise level (DANL) to +20 dBm Input attenuator range 0 to 31 dB, 1 dB steps 

Página 14

 Two -30 dBm tones at input mixer, > 100 kHz tone separation < -96 dBc, +18 dBm TOI (nomina

Página 15

Channel power meter is a built-in power measurement that does not require an external power sensor. Users can set the

Página 16

23FieldFox23General specifications  Type-N (female) Input impedance 50 ohm External reference Input type BNC female R

Página 17

24General specifications continued Environmental Meets MIL-PRF-28800F Class 2 specification Humidity  Temperature   

Página 18

N9912A FieldFox RF analyzerFieldFox RF Analyzer base functions: One port cable and antenna analyzer (4 GHz), broadband calibration, CalReady, sta

Página 19

26  N9910X-800 T-calibration kit, DC to 6 GHz, Type-N (m) N9910X-801 T-calibration kit, DC to 6 GHz,

Página 20

FieldFox27FieldFox Accessories

Página 21

FieldFoxSoft carrying case with backpack and shoulder straps included with a standard N9912A. FieldFox

Página 22

For more information on Agilent Technologies’ products, applications or services, please con-tact your local Agilent office. The complete list is avai

Página 23

3Key differentiatorsIntegrated QuickCal calibrates without a calibration kit CalReady

Página 24

44FieldFoxBacklit keypadquick marker fu

Página 25

FieldFox2.8” D72 mmExternal referenceand external triggerSpacious connector design makes connections fast and simpleRF connec

Página 26

6Key MeasurementsFifty to sixty percent of cell site problems are caused by faulty cables, connectors, and antennas. Degrade

Página 27

7Measurements in the field without the need to manually calibrateEach instrument is CalReady at the RF Out port, immediately following power-on or pres

Página 28

Built-in spectrum analyzerInterference is a major source of cell site problems. Interference can be internal or external, and uplink or downlink. Dow

Página 29 - Certified

9Independent signal source and tracking generatorFieldFox has a built-in independent signal source, with a frequency range of 2 MHz to 4/6 GHz. The si